Subject Area
Electrical Engineering
Article Type
Original Study
Abstract
The combination of a rigid-impulsed Inverter and a synchronous compensator for supplying an isolated AC load, is one of the moet economical solutions for adapting the raw electric energy supplied from a DO link. This system has an oscillating nature due to the lack of synchronisation between the air-gap rotating field and the rotor field inside the compensator machine. The resulting oscillations are actually too small but may lead to system in stability or inverter-failures, They are affected by the system paramters and the applied type of control, This paper presents the energy-loops as a helpful tool in predicting wheather a proposed system of such a structure will maintain stability or not. Thereby an optimal dimensioning of the system parameters can be ensured.
Recommended Citation
Abou-Taleb, Hassan; El-Shamoty, M.; and El-Drieny, S.
(2020)
"Application of Energy Loops to Study the Stability of Synchronous Compensator Coupled with Rigidly Impulsed Inverter to supply Isolated AC Networks.,"
Mansoura Engineering Journal: Vol. 10
:
Iss.
2
, Article 6.
Available at:
https://doi.org/10.21608/bfemu.2021.177216