Subject Area
Mechanical Power Engineering
Article Type
Original Study
Abstract
The present paper describes a numerical procedure and its capability for calculating the film cooling effectiveness by injection from a single transverse row of discrete holes over a flat surface. The three-dimensional calculation procedure takes into account the elliptic nature of the flow after the injection. The effects of turbulence are simulated through the implementation of the standard k-ε turbulence model. Results are given for; two injection angles of 35° and 90o, spacing between the holes of 3 hole diameters, coolant-to-mainstream density ratios of 1.0 and 2.0, and blowing rates from 0.5-2.0. The predicted cooling effectiveness is compared with some available experimental data and shows an overall performance of reasonably good agreement.
Recommended Citation
Ammari, Handry and Hay, N.
(2021)
"Prediction of Film Cooling Effectiveness by a Row of Moles over a Flat Surface.,"
Mansoura Engineering Journal: Vol. 19
:
Iss.
3
, Article 1.
Available at:
https://doi.org/10.21608/bfemu.2021.163753