Subject Area
Civil and Environmental Engineering
Article Type
Original Study
Abstract
This article investigate the effect of long installation on the pile characteristics for cost an-place vibro piles. Twetey one non destructive integrity tests using the mechanical impedance steady state dynamic method were done on 21 piles having long installation time. All tests except one show that the piles considered to be sound. A load test on one pile gives gross settlement of 4 mm under 1.5 of the working load.
Recommended Citation
Bahloul, M.
(2021)
"The Effect of Long Installation on the Pile Characteristics.,"
Mansoura Engineering Journal: Vol. 8
:
Iss.
2
, Article 4.
Available at:
https://doi.org/10.21608/bfemu.2021.180267