Abstract
This study is concerned with investigating the punching shear provisions of ACI 318-08 with emphasis on Equation (11-32) of this code. For reinforced concrete slabs and footings, shear force resisted by concrete is taken as the smallest value evaluated from ACI Equations (11-31), (11-32) and (11-33). Based on the experience of the author in designing isolated footings, it is noticed that Equation (11-32) has never yielded the smallest shear capacity in isolated footing design, thus making this equation redundant in terms of punching shear design. In this work, Equation (11-32) is to be investigated theoretically and parametrically to prove its redundancy in terms of practical design of isolated footings
Keywords
punching shear; Isolated footing; Column dimensions; Column location
Recommended Citation
Shihada, Samir
(2020)
"Investigating ACI 318-08 Punching Shear Provisions for Design of Isolated Footings.,"
Mansoura Engineering Journal: Vol. 35
:
Iss.
1
, Article 21.
Available at:
https://doi.org/10.21608/bfemu.2020.124338